CW CABLE GLAND (3 PART)
We offer quality and durable range of CW Cable Gland (3 PART). These are used both indoor and outdoor, in all climatic conditions, as it is weatherproof & waterproof. Our range is further provided with a wire that is used instead of a knurled cone.
Application:
-
For use with armored cable
-
Secures armoring and provides electrical continuity between armour and gland entry component
-
Also provides a seal on the outer sheath of the cable thus ensuring no damage to cable sheathing
​
Specifications:
-
Design Features: 2 part Armour/Earth Lock, Knurled Armour Lock produces a low resistance earth clip
​
Application : For use with armoured cable, secures armouring and provides electrical continuity between armour and gland entry component. Also provides a seal on the outer sheath of the cable thus ensuring no damage to cable sheathing. These are used both indoor and outdoor, in all climatic conditions as it is weatherproof & waterproof.
Design Features : 2 part Armour/Earth Lock, Knurled Armour Lock produces a low resistance earth clip.
Also available in CIEL(cast integral earth lug) for orders add" C " to prod. code.
![cw-cable-gland-3-part.jpg](https://static.wixstatic.com/media/2214cf_56f3906dc89044978fcf964d6a208b51~mv2.jpg/v1/fill/w_285,h_187,al_c,q_80,enc_avif,quality_auto/cw-cable-gland-3-part.jpg)
![cw-cable-gland-3-part-1-2.jpg](https://static.wixstatic.com/media/2214cf_8fea74a909a54dbeb375833d9418a800~mv2.jpg/v1/fill/w_285,h_187,al_c,q_80,enc_avif,quality_auto/cw-cable-gland-3-part-1-2.jpg)
Size | Cable Dimensions Accommodate | Gland Dimensions | Prod. Code | ||||||
---|---|---|---|---|---|---|---|---|---|
50S | 37.8 | 45 | 50 | 2.00 / 2.50 | 15 | 65 | 51 | 64 | HCW 50 S |
Under Armour | Overall | ISO Entry Thread | Armour | Approx | Hexagon Size | ||||
63S | 50.5 | 60.5 | 63 | 2.5 | 15 | 70 | 70 | 78 | HCW 63 S |
40 | 32.5 | 40.8 | 40 | 1.60/2.00 | 15 | 60 | 49 | 54 | HCW 40 |
50 | 44 | 51.5 | 50 | 2.00 / 2.50 | 15 | 65 | 62.3 | 69.5 | HCW 50 |
mm | mm | Dia | mm | Length | shoulder | Across flat | Across corners | ||
20 S | 12.5 | 17 | 20 | 0.90 / 1.25 | 10 | 47 | 22 | 29 | HCW 20 S |
from | |||||||||
Dia A Max. | Dia. B Max. | wire dia C | length | ||||||
32 | 26.5 | 33 | 32 | 1.60 / 2.00 | 10 | 55 | 41.5 | 46.5 | HCW 32 |
90 | 80 | 90 | 90 | 3.15 | 20 | 90 | 103 | 115 | HCW 90 |
75S | 62.5 | 72 | 75 | 2.5 | 15 | 75 | 85 | 95 | HCW 75 S |
16 | 8.6 | 13.5 | 16 | 0.9 | 10 | 40 | 20 | 23 | HCW 16 |
40 S | 31 | 37 | 40 | 1.60 / 2.00 | 10 | 60 | 45 | 50 | HCW 40 S |
D mm | E mm | F mm | G mm | H mm | |||||
63 | 56.5 | 65.5 | 63 | 2.5 | 15 | 70 | 76.3 | 85 | HCW 63 |
25 S | 17.8 | 23.8 | 25 | 1.25 / 1.60 | 10 | 50 | 31 | 34 | HCW 25 S |
20 | 14.4 | 20.5 | 20 | 0.90 / 1.25 | 10 | 47 | 26 | 29 | HCW 20 |
25 | 20.4 | 27 | 25 | 1.25 / 1.60 | 10 | 50 | 34 | 38.5 | HCW 25 |
75 | 67.5 | 78.5 | 75 | 2.50 / 3.15 | 15 | 75 | 91 | 112 | HCW 75 |